☕How "Multi-Candle" work ?
Normally a condition is checked on one candle only — the candle you pick in "Candle To Check".
Multi-Candle lets you ask for more: the condition must happen n times inside m candles. Use it when one single candle is too easy to trigger, and you want the market to confirm the same thing a few times.

The condition above triggers when RSI is over 70 on at least 2 of the last 3 candles.
Where to find it
Open Add / Edit condition. Right under Candle To Check there is a row:
Tick the checkbox to turn it on. The two selectors appear only after you tick it.
Left selector = n, how many candles must match.
Right selector = m, how many candles to look at.
The line under the row always shows the two ends of the window, so you can read exactly which candles are used.
Some conditions do not call a candle a "candle" — for those the row reads Multi-Bar: … Bars, and so on. It works the same way.
What it means
Candle To Check decides where the window starts.
The window is that candle plus the
m - 1candles before it. It always counts backwards, into the past.The condition is met when at least n candles inside the window match. They do not need to be next to each other.
Current
2 times in 3 Candles
Current, 1 Previous, 2 Previous
2 or 3 of them match
Current
1 times in 5 Candles
Current … 4 Previous
any 1 of them matches
10 Previous
2 times in 3 Candles
10, 11, 12 Previous
2 or 3 of them match
Current
off
Current only
Current matches
Be careful with the direction when you do not start at "Current". With Candle To Check = 10 Previous and 2 times in 3 Candles, the window is 10, 11, 12 Previous — it goes further back in time. It is not 10, 9, 8 Previous. The "Window:" line under the row always spells this out:

Window: 10 Previous to 12 Previous — the window opens at the candle you picked and walks into the past.
Example
Condition: RSI(14) Over 70, Candle To Check = Current, Multi-Candle = 2 times in 3 Candles.
71.2
69.0
70.5
✅ alert — 2 candles above 70 (they are not side by side, that is fine)
65.0
71.5
72.0
✅ alert — 2 candles above 70
71.2
69.0
68.4
❌ no alert — only 1 candle above 70
Which candle is "Current" ?
This follows the Calculation Mode of the alert, exactly like a normal single-candle condition:
At End of Candle (called Closed Candle on a condition row) — "Current" is the last closed candle.
Every Minute (available only when Global Timeframe is MTF) — "Current" is the candle that is still forming, checked every minute.
Rules and limits
Multi-Candle is for indicator conditions. Patterns do not have it, because patterns have no candle option at all.
It appears only for conditions that have Candle To Check. A few conditions let you choose a candle for each side separately; those do not use this row.
m starts at 2. n can be 1 up to m.
The window can never go past the oldest candle we keep for that indicator:
Candle To Check + m - 1must stay inside the "Candle To Check" list. If you move Candle To Check further back, the choices for m get shorter — this is normal, not a bug.Each condition in an alert has its own n and m. You can mix: one condition with Multi-Candle, another without.
Every candle in the window is checked with the same settings as the condition itself (Cross Over / Over / Under …, and the Distance limit if you use one).
Leave the checkbox off to keep the old behaviour — one candle, exactly as before. Alerts you created earlier are not changed.
Works together with "must meet" and "number conditions reach target"
Multi-Candle only decides whether this one condition is true or false right now. After that, your alert combines the conditions the usual way — see How "must meet" & "number conditions reach target" work ?
So 2 times in 3 Candles inside a condition, and 2 of 3 conditions for the alert, are two different things and can be used together.
Good to know
Not enough history (new symbol, or you just changed the timeframe): only the candles that really exist are counted. When the history is too short the alert stays quiet instead of triggering early.
A bigger window does not make the alert fire more often. How often an alert may trigger is decided by the alert's own settings, not by Multi-Candle.
Reading the "Window:" line is the fastest way to be sure: it names the first and the last candle of the window, so there is no doubt about which direction it counts.
The condition text itself carries the setting, so you can check it later without opening the condition again:
Last updated
Was this helpful?
